Napco - Continental Access - Alarm Lock - Marks USA
Alarm System, Wireless Addressable Fire System, Video System, Access Control
System, Alarm Locks
|
|
FIRELINK™ FACP STARLINK-POWERED 8-32 ZONE LTE CELLULAR FIRE ALARM SOLUTION,
FL-FACP32 SERIES
-
Lowest Equipment Cost
Available for Any Full-Featured Cell Reporting Fire Alarm Solution Saves Both
Installation Time & Money FACP: 8 to 32 Zone Conventional Fire Alarm Control
Panel (Firewolf®),
8 conventional fire zones, suitable for 2-wire fire, expandable to 32; 2
programmable NAC circuits, 2A max @ 24V
-
Annunciator: Menu-driven operation with backlit custom alphanumeric display and
functionality for Reset, Acknowledge, Silence (with disable).
-
Cellular LTE Communicator, Commercial Fire (StarLink Fire) Onboard:, reports on
cyber-protected multibillion-dollar cellular networks, for maximum security &
liability protection, code-compliant, replaces 2 POTs lines
-
Patented Signal Boost &
Dual Diversity LTE Cellular Antennae™ for
maximum signal acquisition and null avoidance, receiving signals simultaneously
on both antennae
-
Reports to any Central
Station, via dial up or IP, without any special equipment.Integrated sync and
smart operation support on each NAC for System Sensor® and
Wheelock®Notification
Devices
-
Power Supply, 4A @
24VOut-of-the-Box Preprogrammed, or optional Quickloader® Software
custom programmable. Cloud-based programming coming soon.
- Locking Mercantile
Enclosure for surface mount or recess mounting (between the studs) 16"x 14.25" x
5.2" (H x W x D) without cover. Houses up to 16Ah @ 24V battery backup capacity
36-Month Napco Warranty
Agencies,
Compliance:
UL 864 9th Ed., UL
1635 & NFPA 72 Editions 2016, 2013, 2010, 2007 code, CSFM, NYCFD
For More:
|
|
NAPCO COMMERCIAL™ FIREWOLF-SERIES COMPONENTS FOR 32 TO 255 POINT 24V
COMMERCIAL FIRE SYSTEMS:
FIREWOLF SYSTEMS
-
Main Control board supports up to (2) Addressable SLCs (addressable Signaling
Line Circuit controllers).Fire SLC Loop Controller Fire 4-wire bus for
annunciators and non-SLC (conventional) devices, including 12V devices Power
Supply includes either 4A or 7A @ 24VRS-232 Printer Module for optional onsite
parallel printer Supports up to 7 fire annunciators, GEMC-FK1, mounted anywhere
on the bus. (As few as one annunciator required on system for equipment
savings.)Easy-to-use Gemini-style menu-driven operation with backlit custom
alphanumeric display and functionality for Reset, Acknowledge, Silence (with
disable).
-
Full Keyswitch
SupportSynch module built in on each NAC (System Sensor & Wheelock
protocols)Dual Phone Line built in 2 On board serial ports - one for internet
reporting; one for high-speed local downloading TCP/IP Internet reporting module
Regulated Auxiliary Power Supplies - Commercial fire, 12V regulated 2A or 1.75A
version with plug in transformer Addressable SLC Loop Isolator (optional use -
for some fire applications requiring increased circuit integrity, e.g., meets
Class A, Style 7 loop requirements.Choice of two enclosures - Between the studs
enclosures, recess or surface mount –Larger version supports up to 32 AH at 24V.
Dimensions: 24" x 14.25" x 5.2" (H x W x D) without cover. Removable battery
shelves, accommodate pairs of 7Ah, 7.5Ah and 8Ah batteries, etc.Medium Enclosure
– supports 16 AH at 24V. Dimensions: 16" x 14.25" x 5.2" (H x W x D) without
cover. (16Ah battery backup capacity).
Firewolf Fire Alarm Systems & Communications Specifications Sheet
|
|
INPUTS
Up to 255 Zones.
Zones can come from any of the following initiating devices:
-
Addressable SLC Loop – supports up to (2) 126 point loops Commercial RF Receiver
–Supports Commercial Wireless Fire devices Wireless Smoke Detector Wireless Heat
Detector Conventional 1- to 4-zone EZM Expansion modules on the 4-wire fire bus
or SLC loops Conventional 2-wire or 4-wire smoke detector input module SLC Fire
Devices Supported:Analog Smoke Detector Analog Heat Detector Duct Detector Pull
Station Conventional Zone Module Short Circuit Isolator
OUTPUTS
Up to 96 outputs
- Four on board
Class B or 2 Class A NAC circuits, 2 amps each, total 6.5 amps at 24V Built
in Wheelock and System Sensor NAC sync/strobe/horn protocol allows initial
silence of audible appliances while maintaining visual notification, without
the use of additional modules.Addressable SLC Fire Devices: Supervised
relay, unsupervised relay Fire 4-wire bus devices: 8 zone form C relay
(GEMC-RM3008), 8 open collector output (GEMC-OUT8)
Napco Commercial
Firewolf-Series System Advantages:
- Easy Wire
Compatibility - SLC controller supports shielded, unshielded, twisted and
untwisted wire - ideal for retrofits Longer SLC loop lengths, support more
device loads each, too (see below for distance at maximum device load in
alarm/standby each):10,000 ft. #14AWG 6,200 ft. #16AWG 4,000 ft. #18AWG
Support for Legacy and Existing Notification Appliances -One NAC output
configurable for 12V for compatibility for easy retrofit compatibility UL
Regulated NAC outputs Automatic drift compensation for smoke detectors
Annunciators have flash-able firmware – for updates via Quick loader command
Programmable obscuration level by smoke detector device Smoke Obscuration
Report genererated remotely or locally or in any of 3 ways - Quick loader
device sensitivity report allows the printout of a report for the AHJ
listing the current status of all smoke detectors in the system including
the programmed obscuration level and the actual sensitivity reading for each
device. This report can be generated remotely (uploaded) or locally through
notebook PC or use optional onsite printer.Full line of UL Commercial
Devices for more flexibility & labor-savings Example, Use Gemini Commercial
Wireless 2-input module (GEMC-WL-WD2) to convert any UL listed fire device
into a UL wireless device, ideal for sprinkler supervisories or for use with
pull stations (mounts on top of wall/conduit or in deep single-gang box
(plastic).Separate 7Amp 4-NAC Extender (GEM-NAC7) – 4 onboard NACs with up
to 2A ea., expandable for up to 24 per system. Up to 16Ah total battery
capacity. Regulated 24V Aux. power. Monitors AC, battery trouble, tamper and
ground fault on Napco bus - Also Provides Universal FACP support for easy
standardization in upgrades
System Compliances
-
NFPA 72, UL Commercial Fire, UL864 10th Edition, UL985, CSFM and NYC Fire
Department
-
Certifications
|
|
Why More Dealers Choose StarLink:
Universal Support for All
Panels & FACPs – Fastest ConnectionThere's
a StarLink Cellular or Cell/IP Communicator for all panels today
communicating in 4/2 & Contact ID. Whether you're safeguarding your
RMR-producing accounts for the long term, upgrading from POTS or 3G/CDMA
sunsets, doing takeovers in your area, or just starting a new installation off
right, StarLink is there with Easiest Installation in minutes.
|
|
SSI 2019 Home Automation Deep Dive: Napco's Duane Warehime on Advancements
in Security
|
|
Napco Commercial Fire Systems
|
|
Napco Award-Winning Gemini-Commmercial™ Combination Fire/Security System
|
|
Napco Commercial Fire Cellular Communicators for Fire Alarm Systems
|
|
13945 S.W. 56Th Terrace.
Miami, Florida 33183
(786) 717-6232
www.victorvictor.us
|
|
|
|
|
|
|