FIRELINK™ FACP STARLINK-POWERED 8-32 ZONE LTE CELLULAR FIRE ALARM SOLUTION, FL-FACP32 SERIES

  • Lowest Equipment Cost Available for Any Full-Featured Cell Reporting Fire Alarm Solution Saves Both Installation Time & Money FACP: 8 to 32 Zone Conventional Fire Alarm Control Panel (Firewolf®), 8 conventional fire zones, suitable for 2-wire fire, expandable to 32; 2 programmable NAC circuits, 2A max @ 24V
  • Annunciator: Menu-driven operation with backlit custom alphanumeric display and functionality for Reset, Acknowledge, Silence (with disable).
  • Cellular LTE Communicator, Commercial Fire (StarLink Fire) Onboard:, reports on cyber-protected multibillion-dollar cellular networks, for maximum security & liability protection, code-compliant, replaces 2 POTs lines
  • Patented Signal Boost & Dual Diversity LTE Cellular Antennae for maximum signal acquisition and null avoidance, receiving signals simultaneously on both antennae
  • Reports to any Central Station, via dial up or IP, without any special equipment.Integrated sync and smart operation support on each NAC for System Sensor® and Wheelock®Notification Devices
  • Power Supply, 4A @ 24VOut-of-the-Box Preprogrammed, or optional Quickloader® Software custom programmable. Cloud-based programming coming soon.
  • Locking Mercantile Enclosure for surface mount or recess mounting (between the studs) 16"x 14.25" x 5.2" (H x W x D) without cover. Houses up to 16Ah @ 24V battery backup capacity 36-Month Napco Warranty

Agencies, Compliance:
UL 864 9th Ed., UL 1635 & NFPA 72 Editions 2016, 2013, 2010, 2007 code, CSFM, NYCFD
For More:


NAPCO COMMERCIAL™ FIREWOLF-SERIES COMPONENTS FOR 32 TO 255 POINT 24V COMMERCIAL FIRE SYSTEMS:

FIREWOLF SYSTEMS
  • Main Control board supports up to (2) Addressable SLCs (addressable Signaling Line Circuit controllers).Fire SLC Loop Controller Fire 4-wire bus for annunciators and non-SLC (conventional) devices, including 12V devices Power Supply includes either 4A or 7A @ 24VRS-232 Printer Module for optional onsite parallel printer Supports up to 7 fire annunciators, GEMC-FK1, mounted anywhere on the bus. (As few as one annunciator required on system for equipment savings.)Easy-to-use Gemini-style menu-driven operation with backlit custom alphanumeric display and functionality for Reset, Acknowledge, Silence (with disable).
  • Full Keyswitch SupportSynch module built in on each NAC (System Sensor & Wheelock protocols)Dual Phone Line built in 2 On board serial ports - one for internet reporting; one for high-speed local downloading TCP/IP Internet reporting module Regulated Auxiliary Power Supplies - Commercial fire, 12V regulated 2A or 1.75A version with plug in transformer Addressable SLC Loop Isolator (optional use - for some fire applications requiring increased circuit integrity, e.g., meets Class A, Style 7 loop requirements.Choice of two enclosures - Between the studs enclosures, recess or surface mount –Larger version supports up to 32 AH at 24V. Dimensions: 24" x 14.25" x 5.2" (H x W x D) without cover. Removable battery shelves, accommodate pairs of 7Ah, 7.5Ah and 8Ah batteries, etc.Medium Enclosure – supports 16 AH at 24V. Dimensions: 16" x 14.25" x 5.2" (H x W x D) without cover. (16Ah battery backup capacity). Firewolf Fire Alarm Systems & Communications Specifications Sheet
INPUTS
Up to 255 Zones. Zones can come from any of the following initiating devices:

  • Addressable SLC Loop – supports up to (2) 126 point loops Commercial RF Receiver –Supports Commercial Wireless Fire devices Wireless Smoke Detector Wireless Heat Detector Conventional 1- to 4-zone EZM Expansion modules on the 4-wire fire bus or SLC loops Conventional 2-wire or 4-wire smoke detector input module SLC Fire Devices Supported:Analog Smoke Detector Analog Heat Detector Duct Detector Pull Station Conventional Zone Module Short Circuit Isolator

OUTPUTS
Up to 96 outputs
  • Four on board Class B or 2 Class A NAC circuits, 2 amps each, total 6.5 amps at 24V Built in Wheelock and System Sensor NAC sync/strobe/horn protocol allows initial silence of audible appliances while maintaining visual notification, without the use of additional modules.Addressable SLC Fire Devices: Supervised relay, unsupervised relay Fire 4-wire bus devices: 8 zone form C relay (GEMC-RM3008), 8 open collector output (GEMC-OUT8)
Napco Commercial Firewolf-Series System Advantages:
  • Easy Wire Compatibility - SLC controller supports shielded, unshielded, twisted and untwisted wire - ideal for retrofits Longer SLC loop lengths, support more device loads each, too (see below for distance at maximum device load in alarm/standby each):10,000 ft. #14AWG 6,200 ft. #16AWG 4,000 ft. #18AWG Support for Legacy and Existing Notification Appliances -One NAC output configurable for 12V for compatibility for easy retrofit compatibility UL Regulated NAC outputs Automatic drift compensation for smoke detectors Annunciators have flash-able firmware – for updates via Quick loader command Programmable obscuration level by smoke detector device Smoke Obscuration Report genererated remotely or locally or in any of 3 ways - Quick loader device sensitivity report allows the printout of a report for the AHJ listing the current status of all smoke detectors in the system including the programmed obscuration level and the actual sensitivity reading for each device. This report can be generated remotely (uploaded) or locally through notebook PC or use optional onsite printer.Full line of UL Commercial Devices for more flexibility & labor-savings Example, Use Gemini Commercial Wireless 2-input module (GEMC-WL-WD2) to convert any UL listed fire device into a UL wireless device, ideal for sprinkler supervisories or for use with pull stations (mounts on top of wall/conduit or in deep single-gang box (plastic).Separate 7Amp 4-NAC Extender (GEM-NAC7) – 4 onboard NACs with up to 2A ea., expandable for up to 24 per system. Up to 16Ah total battery capacity. Regulated 24V Aux. power. Monitors AC, battery trouble, tamper and ground fault on Napco bus - Also Provides Universal FACP support for easy standardization in upgrades
System Compliances
  • NFPA 72, UL Commercial Fire, UL864 10th Edition, UL985, CSFM and NYC Fire Department
  • Certifications

Why More Dealers Choose StarLink:

Universal Support for All Panels & FACPs – Fastest ConnectionThere's a StarLink Cellular or Cell/IP Communicator for all panels today communicating in 4/2 & Contact ID. Whether you're safeguarding your RMR-producing accounts for the long term, upgrading from POTS or 3G/CDMA sunsets, doing takeovers in your area, or just starting a new installation off right, StarLink is there with Easiest Installation in minutes.
Napco Security

SSI 2019 Home Automation Deep Dive: Napco's Duane Warehime on Advancements in Security
Napco Commercial Fire Systems

Napco Award-Winning Gemini-Commmercial™ Combination Fire/Security System

Napco Commercial Fire Cellular Communicators for Fire Alarm Systems

13945 S.W. 56Th Terrace.
Miami, Florida 33183
(786) 717-6232
www.victorvictor.us